研究者業績
基本情報
- 所属
- 藤田医科大学 医療科学部 臨床教育連携ユニット 診断機器工学分野
- 学位
- 博士(保健学)(2017年3月 東北大学)
- J-GLOBAL ID
- 202001000934829146
- researchmap会員ID
- R000014408
受賞
5-
2017年3月
-
2015年4月
-
2014年11月
論文
38-
Radiation protection dosimetry 2026年10月7日 査読有り筆頭著者責任著者This study evaluated fetal-region doses and dose distributions for X-ray pelvimetry (Guthmann and Martius methods) using exposure conditions from a nationwide survey in Japan and compared them with those of a low-dose computed tomography (CT) protocol using a realistic late-pregnancy phantom. A pregnancy model phantom combining an anthropomorphic phantom with a custom-made abdominal phantom was used. Real-time dosimeters were placed at 18 sites across three abdominal levels. The low-dose CT protocol showed a nearly uniform fetal-region dose distribution, whereas the X-ray methods showed heterogeneous distributions depending on beam direction and irradiation field. The reported mean fetal-region doses were 1.16 mGy for Guthmann, 4.05 mGy for Martius, 5.21 mGy for the combined X-ray examinations, and 0.69 mGy for low-dose CT. These results indicate that the low-dose CT protocol evaluated in this study produced a lower fetal-region dose than the Guthmann and Martius methods evaluated in this study.
-
Journal of applied clinical medical physics 27(10) e70859 2026年10月 査読有り筆頭著者責任著者BACKGROUND: Accurate assessment of fetal radiation dose during diagnostic X-ray examinations remains challenging because commercially available pregnancy phantoms do not adequately reproduce fetal anatomy or permit organ-specific dose measurements. PURPOSE: The purpose of this study was to develop a pregnant phantom with adjustable fetal presentation and to evaluate its anatomical realism and applicability for fetal dose assessment during pelvic radiography. METHODS: The developed phantom comprised an anthropomorphic phantom, a whole-body fetal phantom, acrylic components, and water-filled plastic bags. The fetal phantom was fabricated using three-dimensional printing technology and incorporated bone-equivalent and soft-tissue-equivalent materials. Fetal presentations could be adjusted to cephalic or breech presentations by repositioning the fetal phantom within the abdominal phantom. Computed tomography (CT) images were acquired to measure CT numbers of the fetal brain, thorax, abdomen, pelvic bone, and surrounding water-filled regions. Absorbed doses were measured using real-time dosimeters placed at five locations in the fetal head and three locations in the fetal abdomen. Dose measurements were performed during pelvic radiography and compared with those obtained using a conventional homogeneous pregnancy phantom. RESULTS: The mean CT numbers of the fetal brain, thorax, abdomen, pelvic bone, and water-filled regions were 2.1, -0.8, -0.4, 323.8, and 1.6 HU, respectively. These values were within the expected ranges for soft tissue and bone and were comparable to those of a conventional homogeneous phantom. During pelvic radiography, the mean absorbed doses measured using the adjustable fetal-presentation phantom were 1.34 mGy in the fetal head and 0.07 mGy in the fetal abdomen for the cephalic presentation, and 0.05 mGy and 1.67 mGy, respectively, for the breech presentation. In comparison, the mean absorbed dose measured in the fetal region of the conventional homogeneous phantom was 2.05 mGy. The findings demonstrated substantial differences in regional fetal dose distribution according to fetal presentation. In particular, the fetal head dose in the cephalic presentation was lower than that measured using the conventional phantom. This difference may be partly attributable to attenuation by the fetal skull; however, the comparison should be interpreted with caution given differences in phantom geometry, internal materials, and dosimeter locations between the two phantoms. CONCLUSION: A novel pregnant phantom with adjustable fetal presentation was successfully developed. The phantom reproduced anatomically relevant structures using realistic bone-equivalent and soft-tissue-equivalent materials and enabled direct dose measurements in specific fetal anatomical regions. Compared with a conventional homogeneous phantom, the developed phantom provided a more detailed assessment of fetal dose distributions and allowed evaluation of the effects of fetal presentation on radiation exposure during pelvic radiography.
-
Physica Medica 135 105021-105021 2025年7月 査読有り筆頭著者責任著者
-
Radiation protection dosimetry 2024年3月14日 査読有り筆頭著者責任著者This study aimed to assess fetal radiation exposure in pregnant women undergoing computed tomography (CT) and rotational angiography (RA) examinations for the diagnosis of pelvic trauma. In addition, this study aimed to compare the dose distributions between the two examinations. Surface and average fetal doses were estimated during CT and RA examinations using a pregnant phantom model and real-time dosemeters. The pregnant model phantom was constructed using an anthropomorphic phantom, and a custom-made abdominal phantom was used to simulate pregnancy. The total average fetal dose received by pregnant women from both CT scans (plain, arterial and equilibrium phases) and a single RA examination was ~60 mGy. Because unnecessary repetition of radiographic examinations, such as CT or conventional 2D angiography can increase the radiation risk, the irradiation range should be limited, if necessary, to reduce overall radiation exposure.
-
日本放射線技術学会雑誌 79(3) 241-251 2023年3月 査読有り橈骨動脈アプローチ(TRA)用L型遮蔽板の効果と適切な使用方法について検討した。当院血管造影室に勤務する看護師16名を対象とした。すべてのアーム角度において、高さ100cmまたは130cmで遮蔽効果が最大となり、高さ40、70cmの遮蔽効果は低かった。L型遮蔽板の配置を変化させた場合、posteroanterior(PA)における遮蔽効果は基準線遮蔽板距離が10cmのとき、高さ100、130、160cmでそれぞれ47%、72%、47%であった。基準線-遮蔽板距離が30cm以上離れると遮蔽効果はすべての高さにおいて30%以下であった。TRA用L型遮蔽板を適切な位置で使用することにより、術者位置における散乱X線を最大89%低減できる可能性が示唆された。従来の防護と併用して使用することで、アーム角度PAやleft anterior oblique/cranialにおいて、すべての高さで90%以上の遮蔽効果が得られた。
MISC
22-
Current Topics in Anesthesiology 2017年2月8日
共同研究・競争的資金等の研究課題
3-
日本学術振興会 科学研究費助成事業 2024年4月 - 2027年3月
-
日本学術振興会 科学研究費助成事業 2021年4月 - 2023年3月
-
日本学術振興会 科学研究費助成事業 2019年4月 - 2021年3月