医学部 乳腺外科

鈴木 紳也

suzuki shinya

基本情報

所属
藤田医科大学 医学部 医学科

J-GLOBAL ID
201801017260459374
researchmap会員ID
7000023874

研究分野

 1

論文

 1
  • Shinya Suzuki, Kazuhiro Moriyama, Yoshitaka Hara, Takuya Hinoue, Yu Kato, Daisuke Hasegawa, Naohide Kuriyama, Tomoyuki Nakamura, Satoshi Komatsu, Chizuru Yamashita, Hidefumi Komura, Osamu Nishida
    Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy 25(4) 401-406 2021年8月  
    Myoglobin, which can cause acute kidney injury, has a relatively high molecular weight and is poorly cleared by diffusion. We compared and examined myoglobin clearance by changing the blood purification membrane and modality in patients with a myoglobin blood concentration ≥ 1000 ng/ml. We retrospectively analyzed three patient groups based on the following three types of continuous hemofiltration (CHF): AN69ST membrane, polymethylmethacrylate (PMMA) membrane, and high-flow hemodiafiltration (HDF) with increased dialysate flow rate using the PMMA membrane. There was no significant difference in clearance in CHF between AN69ST and PMMA membranes. However, the high-flow HDF group showed the highest myoglobin clearance (p = 0.003). In the PMMA membrane, changing the treatment modality to high-flow HDF increased clearance above the theoretical value, possibly due to internal filtration. To remove myoglobin by kidney replacement therapy from patients with hypermyoglobinemia, a modality such as high-flow HDF would be desirable.

講演・口頭発表等

 3