保健衛生学部 リハビリテーション学科
Profile Information
- Affiliation
- Center for Information and Neural Networks (CiNet), Advanced ICT Research Institute, National Institute of Information and Communications TechnologyFujita Health University
- Degree
- Doctor of Philosophy in Engineering(Sep, 2023, Tokushima Bunri University)
- Researcher number
- 60995976
- ORCID ID
https://orcid.org/0000-0001-5031-8728- J-GLOBAL ID
- 202301001805649318
- researchmap Member ID
- R000057302
Research Interests
3Research Areas
2Research History
5-
Apr, 2026 - Present
-
Nov, 2023 - Present
-
Apr, 1996 - Mar, 2026
-
Apr, 2020 - Aug, 2020
-
Apr, 2010 - Aug, 2019
Education
2-
Apr, 2020 - Sep, 2023
Committee Memberships
1-
Apr, 2023 - Present
Awards
2-
Dec, 2024
-
Apr, 2024
Major Papers
6-
Radiological physics and technology, 16(2) 235-243, Jun, 2023 Peer-reviewedLead authorThe purpose of this study was to clarify the appropriate use of a combination of pulse sequences and acoustic noise reduction technology in general-purpose brain magnetic resonance imaging. Five pulse sequences commonly used in brain magnetic resonance imaging examinations-turbo spin-echo T2-weighted imaging, T1-weighted fluid-attenuated inversion recovery, T2-weighted fluid-attenuated inversion recovery, diffusion-weighted imaging, and magnetic resonance angiography-were performed on healthy participants at three vendors where acoustic noise reduction technology was available. The results showed that acoustic noise reduction technology reduced sound pressure levels and altered image quality in all pulse sequences across all vendors' magnetic resonance imaging scanners. Although T2-weighted imaging and T1-weighted fluid-attenuated inversion recovery resulted in little image quality degradation, T2-weighted fluid-attenuated inversion recovery, diffusion-weighted imaging, and magnetic resonance angiography had significant image degradation. Therefore, acoustic noise reduction technology should be used with caution.
-
Magnetic resonance imaging, 63 170-177, Nov, 2019 Peer-reviewedLead authorBACKGROUND: ComforTone is a noise reduction technology used in magnetic resonance imaging (MRI) systems; it suppresses acoustic noise by modifying pulse sequences, which appropriately changes the magnetic field gradient waveforms. Although ComforTone can be used to solve the acoustic noise problems that affect patients who are exposed to acoustic noise from MRI, to the best of our knowledge, the associated technical details have not been published and its effects on acoustic noise reduction remain unclear. PURPOSE: To evaluate the efficacy of acoustic noise reduction and the impact of acoustic noise reduction technology involving magnetic field gradient waveform control on image quality. POPULATION: The study included 18 healthy volunteers (11 males and 7 females; median age, 34 years; age range, 24-51 years). FIELD STRENGTH: 1.5 T Philips Ingenia using a SENSE head-spine coil. ASSESSMENT: The sound pressure level (SPL) and 1/3 octave spectra of MRI acoustic noise with the human head positioned in the iso-center of the MRI system were measured for five different pulse sequences used in clinical MRI. This subjective evaluation of noise included 18 healthy volunteers. The degree of discomfort experienced by the subjects was measured using a visual analog scale. The image quality was assessed objectively and subjectively. For objective assessment, signal-to-noise ratio (SNR) and contrast-to -noise ratio (CNR) of diffusion-weighted images were measured; for subjective assessment, visual evaluation was performed by two radiologists. STATISTICAL TESTS: Data were analyzed using Welch's t-test, and a p value <0.05 defined significance. RESULTS: ComforTone could recognize a decrease in sound pressure, and the sound pressure of the acute high-frequency portion of the auditory characteristics was reduced. As reported by the subjects, discomfort caused by the sound pressure was significantly alleviated with ComforTone (p < 0.01). The sound pressure reduction in the high-frequency region with high audibility characteristics was recognized by ComforTone. The visual evaluation of the image quality of the diffusion-weighted images revealed that although there was no difference between SNR and CNR, the image quality was reduced by distortion artifacts. DATA CONCLUSION: ComforTone reduced the SPL in the frequency range where auditory characteristics were sensitive, suggesting that ComforTone was useful for auditory protection and alleviation of discomfort in patients undergoing MRI. However, because magnetic field gradient waveform control is involved, such noise-reducing techniques should be used by considering their possible influence on the image quality.
Books and Other Publications
1Presentations
41Teaching Experience
1-
Apr, 2010 - Aug, 2020