研究者業績
基本情報
- 所属
- 藤田医科大学 医療科学部 教育企画ユニット 教育企画分野 教授
- 学位
- 博士(医学)(2007年10月 藤田保健衛生大学)
- J-GLOBAL ID
- 200901036417982267
- researchmap会員ID
- 1000226782
研究分野
1論文
34-
Radiation Protection Dosimetry 198(6) 339-348 2022年4月27日 査読有りAbstract During fetal computed tomography (CT) imaging, because of differences in the pregnancy period and scanning conditions, different doses of radiation are absorbed by the fetus. We propose a correction coefficient for determining the fetal size-specific dose estimate (SSDE) from the CT dose index (CTDI) displayed on the console at tube voltages of 80–135 kVp. The CTDIs corresponding to pregnant women and fetuses were evaluated using a Monte Carlo (MC) simulation, and the ratio of these CTDIs was defined as the Fetus-factor. When the effective diameter of a fetus was approximately 10 cm, the Fetus-factor was 1.0. The estimated pregnant SSDE was multiplied by the Fetus-factor to estimate the fetal SSDE, which was compared with the fetal dose obtained by the MC simulation of the image of the fetal CT examination. The fetal dose could be estimated with an error of 31.5% in fetal examinations conducted using helical CT.
-
Physical and Engineering Sciences in Medicine 2020年9月14日 査読有り<title>Abstract</title> Organ-effective modulation (OEM) is a computed tomography scanning technique that reduces the exposure dose to organs at risk. Ultrasonography is commonly used for prenatal imaging, but its reliability is reported to be limited. Radiography and computed tomography (CT) are reliable but pose risk of radiation exposure to the pregnant woman and her fetus. Although there are many reports on the exposure dose associated with fetal CT scans, no reports exist on OEM use in fetal CT scans. We measured the basic characteristics of organ-effective modulation (X-ray output modulation angle, maximum X-ray output modulation rate, total X-ray output modulation rate, and noise modulation) and used them in a Monte Carlo simulation to evaluate the effect of this technique on fetal CT scans in terms of image quality and exposure dose to the pregnant woman and fetus. Using ImPACT MC software, Monte Carlo simulations of OEMON and OEMOFF were run on 8 cases involving fetal CT scans. We confirmed that the organ-effective modulation X-ray output modulation angle was 160°; the X-ray output modulation rate increased with increasing tube current; and no modulation occurred at tube currents of 80 mA or below. Our findings suggest that OEM has only a minimal effect in reducing organ exposure in pregnant women; therefore, it should be used on the anterior side (OEMON,front) to reduce the exposure dose to the fetus.
-
Radiation Protection Dosimetry 188(2) 261-269 2020年1月18日 査読有り<title>Abstract</title> The aim of this study was to investigate differences in volume computed tomography dose index (CTDIvol) and dose-length product (DLP) values according to facility size in Japan. A questionnaire survey was sent to 3000 facilities throughout Japan. Data from each facility were collected including bed number, computed tomography (CT) scan parameters employed and the CTDIvol and/or DLP values displayed on the CT scanner during each examination. The CTDIvol and DLP for 11 adult and 6 paediatric CT examinations were surveyed. Comparison of CTDIvol and DLP values of each examination according to facility size revealed key differences in CT dose between small and large facilities. This study highlights the importance of lowering the dose of coronary artery examination with contrast agent in smaller facilities and of lowering the dose of adult and paediatric head CT without contrast agent in larger facilities. The results of this study are valid in Japan.
-
X-RAY SPECTROMETRY 2019年7月30日 査読有り
-
Radiation Protection Dosimetry 2019年3月 査読有り
-
The British journal of radiology 92(1094) 20180290-20180290 2018年10月 査読有り
-
Radiation Protection Dosimetry 1-8 2017年5月 査読有り
-
Radiation Protection Dosimetry 1-7 2017年2月 査読有り
-
JOURNAL OF RADIOLOGICAL PROTECTION 36(2) N8-N18 2016年6月 査読有り
-
BRITISH JOURNAL OF RADIOLOGY 89(1058) 1-10 2016年1月 査読有り
-
BRITISH JOURNAL OF RADIOLOGY 88(1052) 1-7 2015年 査読有り
-
JOURNAL OF RADIOLOGICAL PROTECTION 34(1) 125-132 2014年3月 査読有り
-
RADIATION PROTECTION DOSIMETRY 146(1-3) 202-205 2011年7月 査読有り
-
Medicine and Biology 150(10) 366-371 2006年10月 査読有り
-
Medicine and Biology 148(8) 11-15 2004年8月 査読有り
-
CLINICAL NUCLEAR MEDICINE 27(12) 909-910 2002年12月 査読有り
-
日本放射線安全管理学会誌 1(1) 45-49 2002年4月 査読有りIn order to estimate the effective dose (E) of a person who may come into close contact to the 123I-IMP patients, exposure rates around 30 adult patients (male: 15, female: 15) were measured with three ionization survey meters (Aloka, ICS-301) at distances of 0.05, 0.5, 1.0 and 1.5m from the patients. Measurements were carried out in 1, 3, 6 and 24h after the administrations of 123I-IMP. Survey meters were set up to the first cervical vertebrae (Level I), xiphoid process (Level II) and anterior superior iliac spine (Level III) of the patients who were standing erect. The maximum dose equivalent (H1cm) rate of107.9μSv/h per 222MBq was recorded in the level II at 0.05m from the patients. Effective half life of 123I-IMP was 11.0h.<BR>The E around the 123I-IMP patient increases in time approaching to a saturated value, which is defined as total E. The tota1 E was calculated from initial H1cm rates and the effective half life; estimated values/222MBq are 949μSv at 0.05m, 195μSv at 0.5m, 76μSv at 1.0m and41μSv at 1.5m.
-
Radioisotopes 49(12) 575-586 2000年12月 査読有り123I-BMIPPと201TlCl心筋SPECTを一度の検査で, かっクロストークの影響なしに実施する方法として二核種連続投与連続撮像法を考案し, その有用性について検討した。123I-BMIPP検査時にあらかじめ201Tlウインドウ (71±7keV) での画像を撮像し, 終了後ただちに投与撮像して得られた201TlCl画像から71±7keVウインドウに混入する123Iの光子散乱成分を差し引くことで補正された201TlCl画像を得ることができる。クロストークの補正精度を検証するため123Iと201Tlの面線源を使用し, 123I画像が201Tl画像に及ぼす影響を検討した。また, 心臓ファントムおよび臨床例についても検討した。結果, 面線源では123lと201Tlの混在比率の変化や散乱体の有無に対し2-3%の誤差で201TlCl画像は復元された。心臓ファントムおよび臨床例でも純粋な201TlCl画像に匹敵する画像が得られ, カウントプロファイルカーブ, polar mapおよび画像のコントラストにおいても純粋な201TlCl画像とほぼ一致した。面線源の実験において, 連続する2回の撮像間で3ピクセル (約1.5cm) までの位置ずれは, 補正後の201TlCl画像の信頼性を損なう恐れはなかった。
-
Annals of Nuclear Medicine 14(1) 25-32 2000年 査読有り
-
Radioisotopes 48(5) 334-340 1999年5月 査読有りIn order to estimate the effective dose (E) of a person who may come into close contact to the 99mTc-GSA patients. Radiation dose rates around 21 adult patients (male: 14, female: 7) were measured with three ionization surveymeters (Aloka, ICS-301) at distances of 0.05, 0.5, 1.0 and 1.5 m from the patients. Measurements were carried out at 0.75, 3.0, 6.0 and 24.0h after the administrations of 99mTc-GSA.Surveymeters were set up to the first cervical vertebrae (Level I), xiphoid process (Level II) and anterior superior iliac spine (Level III) of the patients with their standing erect, The maximum dose equivalent (Hlcm) rate of 64.98μSvh-1 per 185 MBq was recorded in the LevelII. Effective half life of 99mTc-GSA was 5.8h. Total E around the patients were calculated by the initial Hlcm rates and the effective half life. Total E were 285, 62, 23 and 13μSv per 185 MBq at distances of 0.05, 0.5, 1.0 and 1.5m, respectively. E for the first 24h was corresponding to 94.3% of the total E.
MISC
59-
Open Medical Imaging Journal 6 89-96 2012年
書籍等出版物
17講演・口頭発表等
100共同研究・競争的資金等の研究課題
1-
日本学術振興会 科学研究費助成事業 2016年4月 - 2019年3月
教育内容・方法の工夫(授業評価等を含む)
1-
件名放射線関係法規の講義で用いる教科書は内容量が多く、理解しにくい(読みにくい)等の観点から、学生の理解促進のために内容を凝縮・整理した資料を作成する等の工夫を実施している。開始年月日2012/04/01終了年月日2016/07/31概要放射線関連の法令には、診療放射線技師法、医療法、放射線障害防止法、電離放射線障害防止規則等があり、特に放射線障害防止法の法令文は内容量も多く、関連箇所に文章が飛ぶため、学生が理解する上で混乱することが多いという観点から実施。
作成した教科書、教材、参考書
1-
件名放射線関係法規(3学年)の講義資料と放射線保健管理学実験(4学年)の実験テキスト開始年月日2012/04/01終了年月日2016/07/31概要放射線関係法規の講義では、放射線障害防止法令(B5サイズ:146頁)における資料を作成。放射線保健管理学実験では、放射線安全管理を実践する上で役立つテーマを選別し、その手技の習得が目的。
