研究者業績
基本情報
論文
7-
Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy 21(2) 166-172 2017年4月It currently remains unclear whether stroke volume variation (SVV) before hemodialysis (HD) is an independent predictor of decreased blood pressure (BP) during HD. Fifty-two patients were divided into two groups (Decreased BP during HD group: N = 10, Non-decreased BP group: N = 42). Fractional shortening was lower, and mean arterial pressure (MAP) and SVV were higher in the Decreased BP during HD group. A multiple logistic regression analysis identified low fractional shortening, high MAP, and high SVV as independent predictors of decreased BP during HD. The areas under the ROC curves were as follows: 0.849 for MAP, 0.712 for SVV, and 0.893 for MAP and SVV. Optimal threshold values were 93.0 mm Hg for MAP and 17.3 % for SVV. A multivariate regression analysis identified anemia and a longer dialysis vintage as independently related factors for higher SVV. Our results suggest that high SVV is an independent predictor for decreased BP during HD.
-
Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs 17(4) 315-20 2014年12月This study aimed to assess the efficacy of a new pediatric extra-corporeal life support (ECLS) system (Endumo 2000, Heiwa Bussan, Tokyo, Japan) for postoperative management after the Norwood operation. Thirty-three consecutive patients with hypoplastic left heart syndrome or its variant undergoing the Norwood operation between August 2007 and December 2013 were divided into two groups according to available ECLS devices. Before November 2009, pediatric Emersave (TERUMO, Saitama, Japan) was employed as the ECLS device, and 14 patients were operated on during this period (Emersave era: 7 boys; 2.9 kg). After December 2009, Endumo 2000 was employed and 19 patients were operated on (Endumo era: 8 boys, 3.1 kg). The demographic characteristics of both groups showed no significant differences. ECLS was initiated in 7 of 14 patients (50%) during the Emersave era and 7 of 19 patients (37%) during the Endumo era (p = 0.45). Chest reentry for hemostasis during ECLS support was more frequently needed in patients supported by Emersave (5/7) than Endumo (1/7) (p = 0.03). The first ECLS circuit durability of Endumo was significantly longer than that of Emersave (p = 0.01). The survival at discharge rate in patients required ECLS was 0% (0/7) when supported by Emersave, but 57% (4/7) by Endumo (p = 0.02). As a result, the survival at discharge rate was 43% (6/14) in the Emersave era and 79% (14/19) in the Endumo era (p = 0.03). Longer durability and superior antithrombogenicity of the Endumo 2000 contributed to the improvement of surgical outcomes after the Norwood operation.
-
Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs 17(1) 99-102 2014年3月A 5-year-old girl with right atrial isomerism, complete atrioventricular septal defect, hypoplastic left ventricle, double outlet right ventricle, and mixed-type total anomalous pulmonary venous connection with totally occluded left pulmonary veins presented at our center for fenestrated total cavo-pulmonary connection with an extra cardiac conduit at the age of 3 years. Eleven months after the Fontan completion, she developed protein-losing enteropathy (PLE). Spontaneously closed fenestration was thought to be the cause of the PLE, and she underwent revision of fenestration at the age of 5 years. After the operation, PLE did not improve, and newly developed hypoxemia impaired her systemic ventricular function, leading to the initiation of veno-arterial extracorporeal membrane oxygenation (ECMO) with the Endumo(®) system 18 days after the operation to treat her hemodynamic instability. Although the ECMO circuit was changed three times during the first 8 days, the fourth circuit could be used for 74 days without hemolysis and serum leakage, until the patient unfortunately died 82 days after the operation due to multi-organ failure.
MISC
166-
日本アフェレシス学会雑誌 33(Supplement) 196-196 2014年9月26日
-
膜型肺 (34) 44-51 2013年4月症例1:日齢18男児。右側相同に伴う肺動脈閉鎖、機能的単心室に対し左ブラロック・トーシッヒ変法術、右肺動脈形成術を行い、閉胸後に急性心肺不全となった。症例2:日齢67男児。左心低形成症候群に対し日齢2より両側肺動脈絞扼術を行い、日齢23より動脈管狭小化でステントを留置し、日齢67にノルウッド変法、心房中隔欠損孔拡大術を行った。術後の人工心肺離脱が困難でV-A ECMO(Endumo-2000)へ移行し、11日目にECMOを離脱したが、16時間後にVTとなった。症例3:日齢4男児。エブスタイン奇形に対しスターンズ術、右ブラロック・トーシッヒ変法術、動脈管閉鎖術を行った。術後9時間に突然血圧が20mmHg台まで低下した。3例とも心臓マッサージを開始し、ヘパリン急速静注後に超低充填量体外式膜型人工肺(ECMO)システムを用いたV-A ECMOを導入し、心肺停止からそれぞれ15分後、31分後、22分後に体外循環を用いた心肺蘇生法を行った。
-
日本臨床工学技士会会誌 (46) 26-35 2012年10月深部温プローブを用いて、人工肺デバイス表面から人工肺デバイス内部に位置する血液温度(充填液温)のモニタリングを行い、この深部温プローブが内蔵プローブの代用となり得るかについて、温度測定精度(追従性と正確度)を比較検討した。実験用補助循環(ECLS)システムにはEndumo-6000を使用した。充填液は蒸留水を使用し、充填量は480mLとした。遠心ポンプの回転数は3000rpmに設定し、循環流量が3L/minになるように人工肺出口に抵抗をかけて調節した。温度は、人工肺側面(A)と熱交換器側面(B)を深部温プローブで、内蔵プローブ(C)と充填液温(D)をサーミスタプローブで測定した。深部温プローブは、BがAよりも有意にDとの温度差が小さかった。また、BとDの温度差は、CとDの温度差と比較して測定開始から15分以降において同様の推移を示した。
-
日本臨床工学技士会会誌 (46) 36-40 2012年10月自己血管使用皮下動静脈瘻(AVF)作製後の発育に関連する因子について検討した。血液透析を導入するためにAVF作製前後に上肢血管の超音波検査を実施した末期慢性腎不全患者27例を対象とした。年齢は、上腕動脈血流量(FV)と負の相関関係を示した。男性は女性と比較して血管障害あり群の症例数が有意に多く、上腕動脈血管径が有意に高値を示した。上腕動脈面管径とFVに正の相関関係を示した。FVは年齢および血管抵抗指数(RI)と負の相関関係を認め、上腕動脈血管径と正の相関関係を示した。RIは、収縮期最高血流速度(Vpeak)と正の相関関係を示し、FVと負の相関関係を示した。FVが0.4L/min以上の群は、0.4L/min未満の群と比較して、上腕動脈血管径が有意に高値を示し、年齢においては有意に低値を示した。RIが0.6未満の群は、0.6以上の群と比較して、Vpeak、および年齢において有意に低値を示した。
-
医工学治療 24(Suppl.) 101-101 2012年3月
-
体外循環技術 = The journal of extra-corporeal technology 39(1) 1-5 2012年3月1日
-
日本透析医学会雑誌 45(9) 863-871 2012年透析中における経時的な内シャント血流量(flow volume:FV)と実血流量の変動傾向の解析と,透析中にそれらが低下しやすい症例が持つ危険因子の抽出を行った.対象は,維持血液透析患者64例,観察期間は2か月とした.方法は,対象全例に対して,透析(0,1.5,2.5,4.0)時間値に,FV,実血流量,血圧(収縮期,拡張期)を測定し,以下の8項目について検討した.[1]FV,実血流量,血圧の推移,[2]FV,実血流量,血圧の相関解析,[3]対象の分別(FV低下群/不変群),[4]FV低下群/不変群における血圧の推移,[5]FV低下に寄与する因子の抽出(16項目),[6][5]で抽出された因子別のFV推移,[7]石灰化群とFV低下群のシャント静脈拡張率,[8]石灰化・糖尿病の有無別におけるFV推移.検討の結果,FVと実血流量は透析中有意に低下し,両者の間には有意な正相関がみられた(R=0.76).しかし,FVと血圧に相関関係はみられなかった(R=0.17).FV低下に高い寄与率を有する因子を検討した結果,「シャント血管石灰化,ABI異常,糖尿病」が抽出された.中でもシャント血管石灰化の寄与率は高く(x2統計量=15.2),これはシャント血管の拡張機能低下にも大きく関与していた.これらの結果から,実血流量の低下はFV低下に伴うものであり,その要因にはシャント血管石灰化(コンプライアンス低下)が含まれる可能性が高いと考えられた.シャント血管に石灰化を有し,全身性の血管荒廃がみられる症例は,透析中にシャント血流が低下し,予期せぬ透析効率低下を招く危険性がある.
-
体外循環技術 = The journal of extra-corporeal technology 38(2) 160-167 2011年6月1日
共同研究・競争的資金等の研究課題
3-
日本学術振興会 科学研究費助成事業 2024年4月 - 2027年3月
-
日本学術振興会 科学研究費助成事業 2019年4月 - 2020年3月
-
日本学術振興会 科学研究費助成事業 2015年4月 - 2017年3月