Curriculum Vitaes
Profile Information
- Affiliation
- School of Health Sciences, Research Center for Implementation Nursing Science Initiative,, Fujita Health University
- Researcher number
- 30791587
- J-GLOBAL ID
- 201801018972699491
- researchmap Member ID
- B000304207
Research Areas
1Research History
5-
Apr, 2024 - Present
-
Apr, 2019 - Mar, 2022
-
Apr, 2016 - Mar, 2019
Papers
79-
Healthcare (Basel, Switzerland), 12(13), Jun 24, 2024BACKGROUND: Transabdominal ultrasound is used to detect fecal impaction, but the rectum is difficult to visualize without bladder urine or with gastrointestinal gas. OBJECTIVE: We developed a transgluteal cleft approach that is unaffected by these factors and sought to determine if our ultrasound method could detect and classify fecal matter in the lower rectum using this approach. METHODS: We classified ultrasound images from hospitalized patients into four groups: Group 1 (bowed and rock-like echogenic areas), Group 2 (irregular and cotton candy-like hyperechoic areas), Group 3 (flat and mousse-like hyperechoic areas), and Group 4 (linear echogenic areas in the lumen). Stool characteristics were classified as hard, normal, and muddy/watery. Sensitivity and specificity were determined based on fecal impaction and stool classification accuracy. RESULTS: We obtained 129 ultrasound images of 23 patients. The sensitivity and specificity for fecal retention in the rectum were both 100.0%. The recall rates were 71.8% for Group 1, 93.1% for Group 2, 100.0% for Group 3, and 100.0% for Group 4. The precision rates were 96.6% for Group 1, 71.1% for Group 2, 88.9% for Group 3, and 100.0% for Group 4. Our method was 89.9% accurate overall. CONCLUSION: Transgluteal cleft approach ultrasound scanning can detect and classify fecal properties with high accuracy.
-
INNERVISION, 38(5) 19-22, Apr, 2023
Misc.
38-
超音波医学 Supplement, 49, 2022
-
British Journal of Dermatology, 177(3), 2017 Peer-reviewed
-
看護実践学会誌, 27(1) 42-49, Sep, 2014
-
看護理工学会誌, 1(1) 12-20, 2014画像処理を行うBモードビデオ超音波検査法(BV-US)による高感度な誤嚥検出法を開発した。60歳以上の嚥下障害患者42名を対象とした。同時に行なったビデオ蛍光透視法またはビデオ内視鏡の結果と比較した。画像処理法の感度は0.91、特異度は0.94であった。画像処理なしでは誤嚥塊が検出できなかった4つの誤嚥画像では、画像処理により誤嚥が検出できた。画像処理した場合に検出できた誤嚥塊は、画像処理なしで検出できたものに比べて著しく面積が小さく、短軸が短く、主軸が長く、平均照度レベルが高かった。本法は初期嚥下障害患者に対する食物粘度や姿勢の調整にも役立つと考えられた。
Research Projects
10-
Grants-in-Aid for Scientific Research, Japan Society for the Promotion of Science, Apr, 2023 - Mar, 2027
-
科学研究費助成事業, 日本学術振興会, Apr, 2023 - Mar, 2026
-
Grants-in-Aid for Scientific Research, Japan Society for the Promotion of Science, Apr, 2022 - Mar, 2026
-
Grants-in-Aid for Scientific Research, Japan Society for the Promotion of Science, Apr, 2022 - Mar, 2026
-
Grants-in-Aid for Scientific Research, Japan Society for the Promotion of Science, Jun, 2023 - Mar, 2025