CVClient

Osamu Kawanami

  (河南 治)

Profile Information

Affiliation
Professor, Department of Mechanical Engineering, University of Hyogo
Degree
Doctor (Engineering)(Mar, 2004, Osaka Prefecture University)

J-GLOBAL ID
200901018624326584
researchmap Member ID
5000085387

External link

Papers

 77
  • Shunsuke Matsushima, Mutsuki Noda, Sara Kubo, Hironaga Shiraki, Hironori Matsuhisa, Kenji Okada, Osamu Kawanami
    Interdisciplinary CardioVascular and Thoracic Surgery, 41(3), Mar 2, 2026  Peer-reviewed
    Abstract Objectives Various designs are proposed for pulmonary expanded polytetrafluoroethylene (ePTFE) conduits and have been applied in clinical practice. However, experimental data to support them are limited. We conducted an in vitro experiment using a circulatory simulator to evaluate their haemodynamic performance and hydrodynamic characteristics. Methods Three root models with a 24-mm basal ring (A, straight; B, with small sinuses; C, with large sinuses) were 3D-printed. Cusps were uniformly cut out from a 0.1-mm-thick ePTFE membrane and sewn to the inter wall of the models. Model A had a single suture on the free margins near the commissures. Each model was tested with a pump size of 70 mL, 70 beats/min, and arterial pressure of 30/10 mmHg. The valve behaviour was recorded by a high-speed camera, and particle image velocimetry (PIV) was performed in the region behind the model housing section. Results Peak transvalvular pressure gradients were 4.0, 4.8, and 4.3 mmHg (P = .95), and geometric orifice areas were 2.34, 2.38, and 2.46 cm2 (P = .96) in models A, B, and C, respectively. Particle image velocimetry revealed peak instantaneous velocity was 1.69, 1.69, and 1.65 m/s (P = .74) and peak Reynolds shear stress in the midsystolic phase was 56.8, 49.5, and 25.5 Pa (P = .05) in models A, B, and C, respectively. Model C tended to have a lower distribution of turbulent flow than the other models. Conclusions All models exhibited sufficient opening and acceptable Reynolds shear stress values. The sinus contributed to the suppression of turbulent flow, which may lead to an improvement of conduit durability, but its effect was dependent on the sinus size.
  • Tomoki Hirokawa, Tarou Imamura, Osamu Kawanami
    Applied Thermal Engineering, 281 128708-128708, Dec, 2025  Peer-reviewed
  • Tomoki Hirokawa, Takuya Nakano, Osamu Kawanami
    International Journal of Thermal Sciences, 211, May, 2025  Peer-reviewed
  • Osamu KAWANAMI, Takumi KIMURA, Ryoji IMAI
    JAPANESE JOURNAL OF MULTIPHASE FLOW, 38(1) 32-39, Mar 15, 2024  Lead authorCorresponding author
  • Hitoshi ASANO, Haruhiko OHTA, Osamu KAWANAMI, Ryoji IMAI, Koichi INOUE, Koichi SUZUKI, Yasuhisa SHINMOTO, Satoshi MATSUMOTO
    JAPANESE JOURNAL OF MULTIPHASE FLOW, 38(1) 7-14, Mar 15, 2024  

Misc.

 73

Presentations

 48

Professional Memberships

 5

Research Projects

 13

Industrial Property Rights

 2

Social Activities

 17